1100 Summerfield / Contractor’s Select 1100
New Construction Windows
Single Hung
Structural – AAMA 101/I.S 2-97 REPORT #53829.02-701-47
|
|
DP
Rating
|
Test
Size
|
Loads
|
Water
|
Air @
25 MPH
|
|
H – R 15
|
48 x 73
|
±22.5 psf
|
4.50 psf
|
0.15 cfm/ft2
|
|
H – R 20
|
48 x 73
|
±30.0 psf
|
4.50 psf
|
0.15 cfm/ft2
|
|
H – R 30
|
44 x 60
|
±45.0 psf
|
6.00 psf
|
0.10 cfm/ft2
|
|
H – R 35
|
44 x 60
|
±52.5 psf
|
6.00 psf
|
0.10 cfm/ft2
|
|
H – R 35
|
36 x 60
|
±52.5 psf
|
6.00 psf
|
0.10 cfm/ft2
|
|
H – R 20
|
48 x 73
|
±30.0 psf
|
5.25 psf
|
0.15 cfm/ft2
|
|
H – R 25
|
48 x 73
|
±37.5 psf
|
5.25 psf
|
0.15 cfm/ft2
|
|
H – R 30
|
44 x 60
|
±45.5 psf
|
6.00 psf
|
0.10 cfm/ft2
|
|
H – R 40
|
44 x 60
|
±60.0 psf
|
6.00 psf
|
0.10 cfm/ft2
|
|
H – R 35
|
36 x 60
|
±52.5 psf
|
6.00 psf
|
0.10 cfm/ft2
|
|
H – R 50
|
36 x 60
|
±82.5 psf
|
7.50 psf
|
0.10 cfm/ft2
|
|
H – R 50
|
44 x 60
|
±75.0 psf
|
7.50 psf
|
0.10 cfm/ft2
|
|
|
THERMAL – NFRC
100-2001
|
|
U-VALUE
|
CR
|
SIZE
|
47.5 x 59.5
|
|
CLEAR
|
0.52
|
N/A
|
|
E-MAX
|
0.38
|
N/A
|
|
E-MAX PLUS
|
0.34
|
N/A
|
|
|
|
SOLAR PROPERTIES – NFRC-200-2001, 500-2001*
|
|
|
CLEAR
|
E-MAX PLUS
|
SHGC
|
0.60
|
0.31
|
|
VT
|
0.62
|
0.49
|
|
*NFRC solar properties test results are based on the
test window which include frame and glass
|
|
|
|
|
|
|
|
Slider
Structural – AAMA 101/I.S 2-97 REPORT #55192.01-701-47
|
|
DP Rating
|
Test
Size
|
Loads
|
Water
|
Air @
25 MPH
|
|
HS - R 20
|
72 x 48
|
±37.5 psf
|
4.5 psf
|
0.10fm/ft2
|
|
HS - R 35
|
72 x 48
|
±52.5 psf
|
4.5 psf
|
0.10fm/ft2
|
|
|
THERMAL – NFRC
100-2001
|
|
U-VALUE
|
CR
|
SIZE
|
59 x 47
|
|
CLEAR
|
0.51
|
N/A
|
|
E-MAX
|
0.37
|
N/A
|
|
E-MAX PLUS
|
0.34
|
N/A
|
|
|
|
SOLAR PROPERTIES – NFRC-200-2001, 500-2001*
|
|
|
CLEAR
|
E-MAX PLUS
|
SHGC
|
0.60
|
0.30
|
|
VT
|
0.61
|
0.49
|
|
*NFRC solar properties test results are based on the
test window which include frame and glass
|
|
|
|
|
|
|
|
Picture Window
Structural – AAMA 101/I.S 2-97 REPORT #
|
|
DP Rating
|
Test
Size
|
Loads
|
Water
|
Air @
25 MPH
|
|
F-C 40
|
|
±psf
|
psf
|
cfm/ft2
|
|
F-C 45
|
|
±psf
|
N/A
|
N/A
|
|
|
THERMAL – NFRC
100-2001 REPORT #02-016-12142.0-13124.0
|
|
U-VALUE
|
CR
|
SIZE
|
47.5 x 59.5
|
|
CLEAR
|
0.49
|
N/A
|
|
E-MAX
|
0.34
|
N/A
|
|
E-MAX PLUS
|
0.30
|
N/A
|
|
|
|
SOLAR PROPERTIES – NFRC-200-2001, 500-2001*
|
|
|
CLEAR
|
E-MAX PLUS
|
SHGC
|
0.63
|
0.29
|
|
VT
|
0.66
|
0.47
|
|
*NFRC solar properties test results are based on the
test window which include frame and glass
|
|
|
|
|
|
|
|
|
|
|