Sargas / Contractor’s Select
2000
Windows For Replacement
Double Hung Unit
Structural – AAMA 101/I.S 2-97 REPORT # 57195.02-701-47
|
|
DP Rating
|
Test
Size
|
Loads
|
Water
|
Air @
25 MPH
|
|
H – R25
|
48 x 72
|
±37.5
psf
|
6.00 psf
|
0.08 cfm/ft2
|
|
H – R25
|
48 x 72
|
±37.5
psf
|
7.50 psf
|
0.08 cfm/ft2
|
|
H – R30
|
44 x 60
|
±45.0
psf
|
7.50 psf
|
0.08 cfm/ft2
|
|
H – R35
|
44 x 60
|
±52.5
psf
|
7.50 psf
|
0.08 cfm/ft2
|
|
|
THERMAL – NFRC
100-2001
|
|
U-VALUE
|
CR
|
SIZE
|
47.5 x 59.5
|
|
CLEAR
|
Call ViWinTech
|
42
|
|
E-MAX
|
Call ViWinTech
|
52
|
|
E-MAX PLUS
|
Call ViWinTech
|
55
|
|
|
|
SOLAR PROPERTIES – NFRC-200-2001, 500-2001*
|
|
|
CLEAR
|
E-MAX PLUS
|
SHGC
|
Call ViWinTech
|
Call ViWinTech
|
|
VT
|
0.62
|
0.54
|
|
*NFRC solar properties test results are based on the
test window which include frame and glass
|
|
|
|
|
|
|
|
Double Glider
Structural – AAMA 101/I.S 2-97 REPORT # 55821.02-122-47
|
|
DP Rating
|
Test
Size
|
Loads
|
Water
|
Air @
25 MPH
|
|
HS – R30
|
96 x 60
|
±30.0
psf
|
9.00 psf
|
0.13
cfm/ft2
|
|
HS – R30
|
72 x 60
|
±45.0
psf
|
9.00 psf
|
0.15
cfm/ft2
|
|
HS – R20
|
72 x 48
|
±30.0
psf
|
9.00 psf
|
0.15
cfm/ft2
|
|
HS – R35
|
72 x 48
|
±52.5
psf
|
9.00 psf
|
0.15
cfm/ft2
|
|
|
THERMAL – NFRC
100-2001
|
|
|
U-VALUE
|
CR
|
SIZE
|
59.5x 47.5
|
CLEAR
|
Call ViWinTech
|
42
|
|
E-MAX
|
Call ViWinTech
|
53
|
|
E-MAX PLUS
|
Call ViWinTech
|
55
|
|
|
|
SOLAR PROPERTIES – NFRC-200-2001, 500-2001*
|
|
|
CLEAR
|
E-MAX PLUS
|
SHGC
|
Call ViWinTech
|
Call ViWinTech
|
|
VT
|
0.60
|
0.52
|
|
*NFRC solar properties test results are based on the
test window which include frame and glass
|
|
|
|
|
|
|
|
Picture Window
Structural – AAMA 101/I.S 2-97 REPORT # 55821.02-122-47
|
|
DP Rating
|
Test
Size
|
Loads
|
Water
|
Air @
25 MPH
|
|
F – C50
|
72 x 72
|
±75.0
psf
|
9.75
|
0.02 cfm/ft2
|
|
|
THERMAL – NFRC
100-2001
|
|
U-VALUE
|
CR
|
SIZE
|
47.5 x 59.5
|
|
CLEAR
|
Call ViWinTech
|
44
|
|
E-MAX
|
Call ViWinTech
|
56
|
|
E-MAX PLUS
|
Call ViWinTech
|
59
|
|
|
|
SOLAR PROPERTIES – NFRC-200-2001, 500-2001*
|
|
|
CLEAR
|
E-MAX PLUS
|
SHGC
|
Call ViWinTech
|
Call ViWinTech
|
|
VT
|
0.65
|
0.56
|
|
*NFRC solar properties test results are based on the
test window which include frame and glass
|
|
|
|
|
|
|
|
|
|
|