Products Company Technical Media Marketing Service Secure Site Map

6100 Summerfield / Contractor’s Select 6100

New Construction Windows

 

 

 

Double Hung Unit

Structural – AAMA 101/I.S 2-97   REPORT #63801.02-701-47

DP

Rating

Test

Size

Loads

Water

resistance

Air @

25 MPH

H – R 15

52 x 84

±22.5 psf

5.25 psf

0.61 cfm/ft2

H – R 20

52 x 84

±30.0 psf

5.25 psf

0.61 cfm/ft2

H – R 40

36 x 66

±60.0 psf

 7.50 psf

0.61 cfm/ft2

H – R 50

36 x 66

±75.0 psf

 7.50 psf

0.61 cfm/ft2

 

THERMAL – NFRC 100-2001 REPORT #64673.02-116-45
 

U-VALUE

CR

SIZE

47.5 x 59.5

CLEAR

0.46

43

E-MAX

0.34

52

E-MAX PLUS

0.31

55

 

SOLAR PROPERTIES – NFRC-200-2001, 500-2001*

No Grids

CLEAR

E-MAX PLUS

SHGC

0.60

0.30

VT

0.63

0.56

*NFRC solar properties test results are based on the test window which include frame and glass

 

 

 

Glider

Structural – AAMA 101/I.S 2-97   REPORT #51785.02-701-47

DP Rating

Test

Size

Loads

Water

Air @

25 MPH

New Structural testing is being completed and is not available at this time

 

THERMAL – NFRC 100-2001 REPORT #64677.02-116-45
 

U-VALUE

CR

SIZE

59 x 47

CLEAR

0.46

43

E-MAX

0.34

52

E-MAX PLUS

0.30

55

 

SOLAR PROPERTIES – NFRC-200-2001, 500-2001*

No Grids

CLEAR

E-MAX PLUS

SHGC

0.59

0.29

VT

0.61

0.55

*NFRC solar properties test results are based on the test window which include frame and glass

 

 

 

 

Picture Window

Structural – AAMA 101/I.S 2-97   REPORT #51782.02-701-47

DP Rating

Test

Size

Loads

Water

Air @

25 MPH

New Structural testing is being completed and is not available at this time

 

THERMAL – NFRC 100-2001 REPORT #64675.02-116-45
 

U-VALUE

CR

SIZE

47.5 x 59.5

CLEAR

0.47

44

E-MAX

0.33

56

E-MAX PLUS

0.30

59

 

SOLAR PROPERTIES – NFRC-200-2001, 500-2001*

No Grids

CLEAR

E-MAX PLUS

SHGC

0.60

0.30

VT

0.63

0.56

*NFRC solar properties test results are based on the test window which include frame and glass