Products Company Technical Media Marketing Service Secure Site Map

Casement / Contractor’s Select Casement

New Construction & Replacement Windows


 

Single Operating

Structural AAMA 101/I.S 2-97  REPORT #54876.02-701-47

DP

Rating

Test

Size

Loads

Water

Air @

25 MPH

C-C 30

36 x 72

±45.0 psf

12.0 psf

0.01 cfm/ft2

C-C 30

36 x 60

±34.0 psf

12.0 psf

0.01 cfm/ft2

C-C 35

36 x 60

±52.5 psf

12.0 psf

0.01 cfm/ft2

C-R 20

36 x 60

±30.0 psf

12.0 psf

0.01 cfm/ft2

 

THERMAL – NFRC 100-2001
 

U-VALUE

CR

SIZE

Testing for these units have not been completed

CLEAR

E-MAX

E-MAX PLUS

 

SOLAR PROPERTIES – NFRC-200-2001, 500-2001*

 

CLEAR

E-MAX PLUS

SHGC

N/A

N/A

VT

N/A

N/A

*NFRC solar properties test results are based on the test window which include frame and glass

 

 

 

 

Multiple Operating/Stationary

Structural AAMA 101/I.S 2-97   REPORT #54364.02-701-47

DP Rating

Test

Size

Loads

Water

Air @

25 MPH

C-LC25

96 x 72

(XOX)

±37.5 psf

 12.0 psf

0.10 cfm/ft2

C-LC25

64 x 72

(XX)

±37.5 psf

 12.0 psf

0.10 cfm/ft2

C-LC50

48 x 60

(XX)

±75.0 psf

 12.0 psf

0.10 cfm/ft2

 

THERMAL – NFRC 100-2001
 

U-VALUE

CR

SIZE

Testing for these units have not been completed

CLEAR

E-MAX

E-MAX PLUS

 

SOLAR PROPERTIES – NFRC-200-2001, 500-2001*

 

CLEAR

E-MAX PLUS

SHGC

N/A

N/A

VT

N/A

N/A

*NFRC solar properties test results are based on the test window which include frame and glass

 

 

Stationary

Structural AAMA 101/I.S 2-97  REPORT #54876.02-701-47

DP

Rating

Test

Size

Loads

Water

Air @

25 MPH

C-C 30

36 x 72

±45.0 psf

12.0 psf

0.01 cfm/ft2

C-C 30

36 x 60

±34.0 psf

12.0 psf

0.01 cfm/ft2

C-C 35

36 x 60

±52.5 psf

12.0 psf

0.01 cfm/ft2

C-R 20

36 x 60

±30.0 psf

12.0 psf

0.01 cfm/ft2

 

THERMAL – NFRC 100-2001
 

U-VALUE

CR

SIZE

Testing for these units have not been completed

CLEAR

E-MAX

E-MAX PLUS

 

SOLAR PROPERTIES – NFRC-200-2001, 500-2001*

 

CLEAR

E-MAX PLUS

SHGC

N/A

N/A

VT

N/A

N/A

*NFRC solar properties test results are based on the test window which include frame and glass